Cold & Hot Aisle Containment Solutions for Enhanced Cooling Efficiency
We design and deploy advanced aisle containment architectures to optimize airflow, reduce thermal mixing, and significantly improve data centre cooling efficiency.
Technical Scope Includes
Cold Aisle Containment (CAC):- Enclosure of cold aisles with roof panels, aisle doors, end-of-row sealing, and panel systems.
- Ensures uniform cold air delivery directly to IT equipment intakes. Hot Aisle Containment (HAC):
- Containment of hot aisles to isolate and redirect hot exhaust air back to return systems or ceiling plenums.
- Prevents recirculation and reduces cooling load. Containment Structural Solutions:
- Modular aluminium framing, fire-rated polycarbonate panels, tempered glass doors, magnetic and brush seals.
- Fire & smoke detection integration and auto-drop systems compliant with fire safety standards. Airflow Engineering & Optimization:
- CFD-based airflow studies to model thermal patterns and hotspot mitigation.
- Rack blanking panels, cable grommets, and bypass airflow elimination. Efficiency Outcomes:
- Improved cooling effectiveness, reduced PUE, increased rack density, and extended equipment lifespan.
Raised Floor Systems & Cold Air Lock Installations
We design and implement raised flooring and air-lock solutions to manage underfloor cold air distribution and preserve cooling efficiency.
Technical Scope
- High-strength steel or calcium sulphate raised floor panels with anti-static surface finishes.
- Stringer/grid systems designed for load-bearing capacity to support racks and heavy equipment.
- Underfloor plenum design for pressurized cold air supply.
- Installation of perforated tiles, directional airflow tiles, and high-static-pressure tiles.
- Cold air locks at data hall entry points to prevent warm air intrusion and pressure imbalance.
- Sealing of cable cut-outs and floor penetrations to avoid air leakage.
- Integration with CRAC/CRAH airflow delivery systems for optimal cooling distribution.
Supply & Installation of Cooling Equipment
We procure, deploy, and commission the full range of precision cooling systems required for data centre thermal management.
Cooling Equipment Expertise
- Precision Cooling Units: CRAC (DX or chilled water), CRAH units, in-row cooling, rear-door heat exchangers.
- Chiller Systems: Centrifugal, screw, and scroll chillers, integrated with cooling towers or dry coolers.
- Close Control Units (CCUs): For constant temperature & humidity control.
- Economizers: Air-side and water-side economization for energy-efficient cooling.
- High-Density Cooling Solutions: Rear-door cold plates, liquid-to-rack cooling, and hybrid cooling.
- Mechanical installation, insulation, refrigerant piping, condensate drainage, pressure testing.
- Electrical installation, control wiring, and sensor networks.
- Integration with BMS/IBMS for monitoring of temperature, humidity, alarms, and energy usage.
- Full T&C, including airflow testing, leak testing, synchronization, and performance verification.
Installation & Commissioning Scope:
HVAC Works
We execute complete HVAC solutions suited for data centres, commercial buildings, and industrial facilities.
Technical Scope:
- Design & installation of AHUs, FCUs, PAC units, and fresh air systems.
- Ducting (GI, aluminium, insulated, flexible) with dampers, diffusers, grills.
- Chilled water piping, valves, pumps, strainers, insulation.
- HVAC control systems: VFDs, actuators, sensors, thermostats, and controllers.
- Cleanroom and environment-specific HVAC systems.
- Heat load calculation, air balancing, and compliance with ASHRAE standards.
- HVAC redundancy (N+1, 2N), filtration systems, and IAQ management.
Piping Solutions
We provide complete mechanical piping solutions to support cooling, water, and gas systems.
- Chilled Water Piping: MS, GI, HDPE, PPR, or copper piping with thermal insulation.
- Refrigerant Piping: Copper piping for DX systems including brazing, nitrogen purging, and pressure testing.
- Drain & Condensate Lines: PVC/HDPE lines with slope design and proper termination.
- Pump Sets & Valves: Installation of balancing valves, butterfly valves, NRVs, Y-strainers, actuated valves.
- Hydronic Systems: Pump selection, header design, flow balancing, zone separation.
- Support & Hanger Systems: Vibration isolation, seismic supports, and alignment corrections.
Panel Cooling Systems (Up to 6 kW)
We supply and maintain a comprehensive range of high-efficiency power backup and conditioning systems:
Panel cooling systems are engineered to maintain temperature stability inside electrical control panels, MCC panels, PLC cabinets, VFD panels, and automation enclosures. These systems prevent overheating of sensitive electronic components, ensure uninterrupted operation, and extend equipment lifespan. Our panel coolers are available in capacities up to 6 kW, suitable for industrial, commercial, and mission-critical environments.